LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
G9SA-321-T30 user's manual ()
Product model: G9SA-321-T30
Name: Safety Relay Unit
Brand: OMRON
Sort: user's manual
File language: English
I/O SSRs That Mount to OMRON’s G7TC I/O Block.
Input and output modules are available in wide variety.
Snaps easily into P7TF I/O Terminals and can be used together,
with G7T I/O relays.
Operation of each SSR can be monitored easily through an LED indicator.
Models certified for UL and CSA added to the series ("-US" models) G9SA-321-T30 user's manual. Isolation method: Relay.
Zero cross function: No G9SA-321-T30
Operation indicator: Yes.
Applicable output load(See note.): 5 A 100 to 240 VAC.
Rated input voltage: 5 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations G9SA-321-T30 user's manual.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions G9SA-321-T30 user's manual.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays. Safety instantaneous output: 2 (Semiconductor).
Safety slow-speed/stopping detection output: 2 (Semiconductor).
Auxiliary output: 4(Semiconductor).
Maximum set threshold: 10 Hz.
voltage Rated: 24 VDC.
Terminal block type: Spring-cage terminals.
Low-speed Monitoring Function Ensures.
Safety for Maintenance Work.
Motor rotation speed detected by Proximity Sensor.
Monitors and confirms that speed does not exceed the preset level.
Includes an Enabling Switch input for maintenance work.
Detailed LED indications enable easy fault diagnosis.
Safety Category 3 (EN954-1), PLd(ISO13849-1),
SIL 3 (IEC/EN 62061) certified. Terminal (Wire connection): Screw terminal.
Classification: Microloads.
Latching lever (Test switch): No.
Rated input voltage: AC, 100V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA usinng Au-plated G9SA-321-T30 Manual.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed locatiion) G9SA-321-T30 Manual.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging.
Related products
OMRON
Safety Relay Unit
G9SA-321-T075
OMRON Safety Relay Unit G9SA-321-T075
Main contacts: 3PST-NO. OFF-delay conta
OMRON
Safety Relay Unit
G9SA-301
OMRON Safety Relay Unit G9SA-301
Main contacts: 3PST-NO. Auxiliary conta
OMRON
Safety Relay Unit
G9SA-321-T30
OMRON Safety Relay Unit G9SA-321-T30
Main contacts: 3PST-NO. OFF-delay conta
OMRON
Safety Relay Unit
G9SA-321-T15
OMRON Safety Relay Unit G9SA-321-T15
Main contacts: 3PST-NO. OFF-delay conta