Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes.
Applicable output load(See note 2.): 90 A at 24 to 220 VAC (at 40°C).
Rated input voltage: 5 to 24 VDC.
SSR with output (5 to 90 A) at a reasonable price
Zero cross function enables less noise operation.
Built-in varistor effectively absorbs external surges G3PW-A260EC-S-FLK INSTRUCTION MANUAL.
Operation indicator enables monitoring operation
G3PW-A260EC-S-FLK
Protective cover for greater safety.
Certified by UL, CSA and TÜV.Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Screw mounting.
Applicable load: 45 A, 200 to 480 VAC.
Number of pole: 3 G3PW-A260EC-S-FLK INSTRUCTION MANUAL.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track G3PW-A260EC-S-FLK INSTRUCTION MANUAL.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Isolation: Photo-voltage coupler.
Zero cross function: No.
Indicator: Yes.
Rated output load: 0.5 A at 24 to 240 VAC, 0.5 A at 24 to 110 VDC.
Rated input voltage: 12 VDC.
100-A-max. Leakage Current, No Bleeder.
Resistor Required.
1 mA to 500 mA micro-load switching.
Switch to both AC and DC with no polarity.
Switch for a wide range of voltages; 19.2 to 264 VAC, 19.2 to 125 VDC.
Switch full- and half-wave rectifier AC loads.
Same sizes and terminal arrangements as OMRON Power,
Relay MY Series.
Operating indicator provided.
Switch MY Series (without bleeder resistor).
Superior surge absorption with a built-in varistor.
Optimum SSR to control minute load, valves, and solenoids. Soft-start/stop Function Starts and Stops.
Three-phase Mootors Smoothly and G3PW-A260EC-S-FLK Manual.
Economically.
Function like an inverter by holding down the starting current.
Comply with UL, CSA, IEC (400-V models only), and JEM.
requirements.
Mount with screws or to DIN tracks.
Compact monobloock construction for the G3J-T217BL G3PW-A260EC-S-FLK Manual.
(W: 100 × H: 100 × D: 110 mm) with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.