Safety outputs *3: Instantaneous, 2(semiconductor);
OFF-delayed *2: 2 (semiconductor).
Auxiliary outputs *4: 6 (semiconductor).
Logical AND connection: Inputs, 1 (semiconductor);
Outputs, 1 (semiconductor).
Max.OFF-delay time *1: 15 s.
Rated voltage: 24 VDC.
Terminal block type: Spring-cage terminals G3J-205BL-2 INSTRUCTION MANUAL.
A Safety Measure for Hazardous Operations.
That Does Not Lower Productivity
G3J-205BL-2
Two functions support two types of application:
Auto switching: For applications where operators work,
together with machines.
Manual switching: For applications with limited operations.
External indicator outputs enable indicating the switching status,
of two safety input devices.
Auxiliary outputs enable monitoring of safety inputs, safety,
outputs, and errors G3J-205BL-2 INSTRUCTION MANUAL.
Detailed LED indications enable easy diagnosis.
Logical AND connection allows complicated applications in,
combination with other G9SX-series Units.
Certification for compliance with IEC/EN 61508 (SIL3), IEC/EN,
62061 (SIL3) and EN ISO13849-1 (PLe/Safety Category 4). Type: Standard.
Sealing: Flux-tight.
Poles: 6 poles.
Contact configuration: 4PST-NO, DPST-NC G3J-205BL-2 INSTRUCTION MANUAL.
Rated voltage: 12, 18, 21, 24, 48, 110 VDC.
Compact, Slim Relays Conforming to,
EN Standards.
Relays with forcibly guided contacts,
(EN50205 Class A, certified by VDE).
Supports the CE marking of machinery (Machinery Directive).
Helps avoid hazardous machine status when used as part of,
an interlocking circuit.
Four-pole and six-pole Relays are available.
The Relay’s terminal arrangement simplifies PWB pattern design.
Reinforced insulation between inputs and outputs.
Reinforced insulation between some poles of different polarity. Terminal (Wire connection): Push-In Plus Terminal.
Classification: Standard.
Latching lever (Test switch): No.
Rated input voltage: AC/DC, 48V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA usiing Au-plated G3J-205BL-2 Manual.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed locatiion) G3J-205BL-2 Manual.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging.