E5EN-Q3H01TD-FLK-N INSTRUCTION Manual ()
Product model: E5EN-Q3H01TD-FLK-N
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Appearance: Shielded, M12.
Sensing distance: 3 mm.
Output configuration: DC 2-wire.
Operation mode: NO.
Spatter-resistant Fluororesin,
coated Proximity Sensor.
Superior spatter resistance.
Long Sensing-distance Models added for sensing,
distances up to 15 mm.
Pre-wired Smartclick Connector Models are also available E5EN-Q3H01TD-FLK-N INSTRUCTION Manual. Power supply voltage: AC/DC power supply selectable type E5EN-Q3H01TD-FLK-N
Sensing method: Through-beam (Emitter + Receiver).
Sensing distance: 5 m.
Output configu ration: Relay.
Long-distance Photoelectric Sensor.
That Supports AC/DC Power Supplies.
Long sensing distance that is approximately 8,
times that of our conventional model (for the,
Through-beam and Diffuse-reflective models) E5EN-Q3H01TD-FLK-N INSTRUCTION Manual.
(Through-beam: 40 m, Retro-reflective: 7 m, and,
Diffuse-reflective: 2.5 m.) .
Improved visibility:
A red LED that makes the spot visible.
Large indicators that can be seen even from a,
distance.
Improved operability.
(Enlarged sensitivity adjuster and operation selector)
Freely selectable power supply input (24 to 240 VDC, 24 to 240 VAC).
(Additional types added to the DC type lineup E5EN-Q3H01TD-FLK-N INSTRUCTION Manual. )
Models with infrared LEDs are also available. Control output: relay output.
Auxiliary output: -.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapterr cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E5EN-Q3H01TD-FLK-N Manual.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete E5EN-Q3H01TD-FLK-N Manual.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).