LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
E5EN-HSS2HH03BD-FLK INSTRUCTION Manual ()
Product model: E5EN-HSS2HH03BD-FLK
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 4.8 dia.
Protective tubing length L: 35 cm.
Lead wire type: Standard.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5EN-HSS2HH03BD-FLK INSTRUCTION Manual.
Ideal for the thermal input devices of Temperature Controllers E5EN-HSS2HH03BD-FLK
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: Shielded, M8.
Sensing distance: 1.5 mm.
Model: Output configuration: NPN NC.
Highly Durable Proximity Sensor for E5EN-HSS2HH03BD-FLK INSTRUCTION Manual.
Tough Environments.
Completely stainless-steel housing.
Aluminum chip immunity.
Embedding installation to metal (steel) fittings.
Chemical resistance certified by Ecolab Europe.
Lineup includes pre-wire models and DC 3-wire NPN output,
models with fluororesin coating. Item: Advanced models, External input models.
Functions: Remote setting, Counter, Differential operation E5EN-HSS2HH03BD-FLK INSTRUCTION Manual.
Model: NPN output.
Variable Laser Beam for Spot, Line, or Area Detection.
Long-distance detection (diffuse reflective: 1 m, retro-reflective: 7 m).
Beam shape selectable from spot, line, and area types to match various applications.
Adjustable spot diameter.
Adjustable optical axis.
The E3DC-LDA0, which supports the EtherCAT Sensor.
Communications Unit and the CompoNet Sensor.
Communications Unit, is also included in product lineup. The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furtherr performance improvement E5EN-HSS2HH03BD-FLK Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5EN-HSS2HH03BD-FLK Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products