E5EN-HAA2HBD-W INSTRUCTION Manual ()
Product model: E5EN-HAA2HBD-W
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Type: temperature measurement impedance type.
Adjustment mode: ON/OFF action or PID action.
Alarm: there.
Output: relay output.
Digital universal single display electronic temperature controller DIN 48 * 48mm self tuning (self-tuning) PID control. "Classification: Low-cost Models.
Description: Low-cost thermocouple E5EN-HAA2HBD-W INSTRUCTION Manual.
Temperature range (See note 3.): 0°C to 400°C E5EN-HAA2HBD-W
Element type: K (CA) J (IC).
Conductor type: Grounded type.
Class: 2 (0.75).
Protective tubing material: SUS304.
Terminal type: Exposed lead wires.
Page: 20.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5EN-HAA2HBD-W INSTRUCTION Manual.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Appearance: Shielded, M8.
Sensing distance: 2 mm.
Model: Output configuration: NPN NC.
Long-distance Proximity Sensor.
Long-distance detection at up to 30 mm enables secure mounting,
with reduced problems due to workpiece collisions E5EN-HAA2HBD-W INSTRUCTION Manual.
No polarity for easy wiring with DC 2-wire models.
Cable protector provided as a standard feature. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or resistance thermometer.
Auxiliary outputs: None.
Control output 1: Voltage output (for driving SSR).
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0. E5EN-HAA2HBD-W Manual. 5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
mannual, RUN/STOP, and alarms) and the PV or SV E5EN-HAA2HBD-W Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.