LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
E5EN-C3T-W-N INSTRUCTION Manual ()
Product model: E5EN-C3T-W-N
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
E32-T22B type: standard type; resistance to twists and turns,
Features: with 1.5 cylinder (small),
Shape / detection distance (mm): 240; 200; 110 (45),
Bending radius (mm): B; R4.
Standard test object (minimum test object) (mm) 1: 0.5 (0.005),
Fiber element for meeting diversified needsName: Temperature Controller (See note 1 E5EN-C3T-W-N INSTRUCTION Manual. ).
Power supply: 24 VDC.
No. of control points: 2 E5EN-C3T-W-N
Control output: Transistor output.
Auxiliary output: Transistor output: 2 pts (sourcing).
Functions: Heater burnout alarm (See note 3.), Heating or heat/cool,
control is selectable (See note 4.)Event input: 1 point per Unit.
Communications functions: RS-485.
Input type (See note 5.): Thermocouple.
New DIN Track Mounting Temperature E5EN-C3T-W-N INSTRUCTION Manual.
Controller.
Two channels of temperature control available despite width of,
only 22.5 mm.
The Temperature Controller itself can be replaced without,
changing terminal wiring.
Use in combination with a compact Setting Display Unit to,
reduce communications programming requirements.
Front-panel LED indicators for easy operation monitoring.
Power supply and communications wiring not required between,
Units when mounted side-by-side E5EN-C3T-W-N INSTRUCTION Manual.
CompoWay/F communications protocol supported.
UL, CSA, and CE Marking compliance. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of thee Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5EN-C3T-W-N Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5EN-C3T-W-N Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products