LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
E5EN-C3L-N INSTRUCTION Manual ()
Product model: E5EN-C3L-N
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Element type: J (IC).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 8 dia.
Protective tubing length L: 35 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5EN-C3L-N INSTRUCTION Manual.
Ideal for the thermal input devices of Temperature Controllers E5EN-C3L-N
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Type: Master Connector.
Cable length: 2 m.
Number of conductors: 3.
Easy and optimum settings for anyone.
Smart Fiber Amplifier Unit with Long-term Stable Detection E5EN-C3L-N INSTRUCTION Manual.
Equipped with Smart Tuning, which automatically configures the,
settings to their optimum values with the press of a single button.
Highly usable design enables anyone to configure the settings easily.
Detects dirt, vibrations, and LED deterioration, and automatically,
compensates the incident level and the light intensity.
Unparalleled best-in-class power provides stable detections for low,
reflective workpieces and large workpieces (equipped with GIGA RAY II) E5EN-C3L-N INSTRUCTION Manual. Size: M12 (Brass); Double; Shielded (See note 2.).
Sensing distance: 16 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications. Sensing method: Diffuse-reflective Sensors.
Appearance: Horizontal.
Connection method: Pre-wired.
Sensing distance: 100 mm (wide view).
Functions: --.
Model: NPN output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo)) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5EN-C3L-N Manual.
Through the infrared port can be carried out from the frront of the communication E5EN-C3L-N Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products