LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
E5CN-Y2HBT User's Manual (Communications Functions)
Product model: E5CN-Y2HBT
Name: Temperature Controller
Brand: OMRON
Sort: Communications Functions User's Manual
File language: English
E3F3-T86 detection methods: the firing pattern,
Lead extraction: CN M12,
Type: Plastic appearance; PNP output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologySize: DIN 1/4, 96 x 96 x 78mm E5CN-Y2HBT User's Manual.
Power supply voltage: AC100 ~ 240V.
Alarm points: 3 points E5CN-Y2HBT
Control output: voltage output (for driving a bidirectional thyristor switching element).
Input: Platinum resistance.
New generation intelligent general temperature controller.
The thickness is only 78 mm.
Various temperature inputs: thermocouple, platinum resistance, non contact temperature sensor signal input.
Automatic adjustment and self adjustment E5CN-Y2HBT User's Manual.
Automatic adjustment can be performed even when the self adjustment is being performed.
Can use heating or heating / cooling control.
Event entry allows multiple SP options and run / stop functions. Name: HFU with Programless Communications *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None E5CN-Y2HBT User's Manual.
Auxiliary output: Transistor output: 4 points (sinking).
Functions: burnout Heater alarm, None; Event inputs, 4.
Communications functions: Port C: RS-422,
From End Unit: Port A: RS-485.
Input type: No input.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to thee G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E5CN-Y2HBT MANUAL.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculaate the PID constants with the step,
response method E5CN-Y2HBT MANUAL.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.