E5CN-R2TU INSTRUCTION Manual ()
Product model: E5CN-R2TU
Name: temperature controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
A New High-performance Controller: High Resolution, High Speed,
and High Input Accuracy.
Logic Operations and Preventive.
Maintenance Function.
High-resolution display with 5 digits/0.01°C display in a compact,
Controller (48 x 48 mm).
High-speed sampling cycle of 60 ms.
High Accuracy,
Thermocouple/Pt input: ±0 E5CN-R2TU INSTRUCTION Manual. 1% of PV,
Analog input: ±0.1% FS,
Universal inputs on all models (thermocouple, PT, or analog,
input) to handle various sensors with one Controller E5CN-R2TU
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Flexible contact outputs with logic operations (AND, OR, and,
delays) set from the Support Software (CX-Thermo Ver E5CN-R2TU INSTRUCTION Manual. 4.0),
Preventive maintenance for relays in the Temperature.
Controller using a Control Output ON/OFF Counter. E32-TC200FR type: standard type; soft (new standard),
Specialty: M3 screw (small) with casing,
Shape / detection distance (mm): 160; 130; 75 (30),
Standard test object
(minimum test object) (mm) 1: 0.5 (0 E5CN-R2TU INSTRUCTION Manual. 005),
Fiber element for meeting diversified needsE3F3-D66 detection method: diffuse reflection type,
Lead extraction: CN M12,
Type: Plastic appearance; NPN output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologySize: 48 x 24mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC/DC24V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The coonnection method can be selected from a screw terminal and a PUSH-IN fastening terminal E5CN-R2TU Manual.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsion Village (sold separately) connected to the computer after,
No power connection can be set E5CN-R2TU Manual.
It can be easily set by CS-Thermo (sold separately).
Related products
OMRON
High performance temperature controller
E5CN-HC2B
OMRON High performance temperature controller E5CN-HC2B
Size: 48 x 48mm. Body: terminal type. Ca
OMRON
Foundation type temperature controller
E5CN-R2HBLD
OMRON Foundation type temperature controller E5CN-R2HBLD
Ontology: terminal type, analog input ty