E5CN-R2H03T-FLK USER'S MANUAL ()
Product model: E5CN-R2H03T-FLK
Name: Temperature Controller
Brand: OMRON
Sort: USER'S MANUAL
File language: English
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E5CN-R2H03T-FLK USER'S MANUAL E5CN-R2H03T-FLK
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E5CN-R2H03T-FLK USER'S MANUAL.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E5CN-R2H03T-FLK USER'S MANUAL. , can be a key operation. Element type: J (IC).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 15 dia.
Protective tubing length L: 100 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Continuation of the E6B2 high cost, value also have more choice.
E6B3, E6C4 blockbuster debut! Complementary output of the first starting high anti interference.
40mm diameter, shaft diameter of phi 8mm universal, with strong axial load capacity.
50mm diameter, shaft diameter of phi 10mm rugged, with strong axial load capacity,
At the same time, the use of IP65 anti drip, anti oil structure.
E6B2 complementary output will be issued over the same period.
Connection length to reach a full 30m!
Resolution (pulse / rotatioon):10~3600P/R E5CN-R2H03T-FLK MANUAL.
Power supply voltage: DC12 ~ 24V
Consumption current: 100mA below.
Output state: complementary output.
Maximum response frequency: 100kHz.
Output phase difference: A phase, B phase difference 90 plus or miinus 45 E5CN-R2H03T-FLK MANUAL.
Starting torque: M / 10mN below (at room temperature).
Maximum allowable speed: 5000r/min.
Axial force: radial...... 120N, axial...... 50N.