Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5CC-TRX3DSM-060 INSTRUCTION Manual
E5CC-TRX3DSM-060
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E5CC-TRX3DSM-060 INSTRUCTION Manual.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E5CC-TRX3DSM-060 INSTRUCTION Manual. , can be a key operation. Liquid Level Sensor That Is.
Unaffected by the Color of the Pipe or.
Liquid.
Mount to bypass pipes.
Fit a wide range of pipe diameters: 8 to 11 mm or 12 to 26 mm.
Built-in Amplifiers to save space. Item: Mark-detecting models (multiple color light sources); Infrared LED.
Functions: Timer, Response speed change.
Model: PNP output.
Advanced Fiber Amplifier Units.
Features a Power Tuning function that optimizes light,
reception at the press of a button.
APC circuits to suppress LED aging degradation used with,
4-element LEDs.
2-channel models achieve the thinnest* profile in the industry,
at only 5 mm per channel.
2-channel models also offer AND/OR control output.
The E3X-MDA0 with two channels supports an EtherCAT Sensor.
Communications Unit or CompoNet Sensor Communications Unit. Size: M30, Non-shielded.
Sensing distance: 20.0 mm.
Connection: Pre-wired.
Body material: Brass.
Thread length (overall length): 44 (64)(See note.).
Output configuration: NPNN E5CC-TRX3DSM-060 Manual.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpiecees are eliminated E5CC-TRX3DSM-060 Manual.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization.