LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
E5CC-RW1AUM-000 INSTRUCTION Manual ()
Product model: E5CC-RW1AUM-000
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 4.8 dia.
Protective tubing length L: 50 cm.
Lead wire type: Heat resistive.
Lead wire length M: 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5CC-RW1AUM-000 INSTRUCTION Manual.
Ideal for the thermal input devices of Temperature Controllers E5CC-RW1AUM-000
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 35 cm E5CC-RW1AUM-000 INSTRUCTION Manual.
Lead wire type: Standard.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CC-RW1AUM-000 INSTRUCTION Manual. Appearance: Shielded, M18.
Sensing distance: 7 mm.
Output configuration: DC 2-wire (1)-(4) pin arrangement.
Operation mode: NO.
Spatter-resistant Fluororesin,
coated Proximity Sensor.
Superior spatter resistance.
Long Sensing-distance Models added for sensing,
distances up to 15 mm.
Pre-wired Smartclick Connector Models are also available. Size: 48 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event entry point: 4.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuual, RUN/STOP, alarm), interactive display PV/SV E5CC-RW1AUM-000 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CC-RW1AUM-000 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.