E5AN-R3HMT-500 INSTRUCTION Manual ()
Product model: E5AN-R3HMT-500
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 20 cm.
Lead wire type: Standard.
Lead wire length M : 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5AN-R3HMT-500 INSTRUCTION Manual.
Ideal for the thermal input devices of Temperature Controllers E5AN-R3HMT-500
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. E3JM-R4M4 detection method: Regression reflection type with M.S.R. function,
Connection: terminal plate,
Detection range: 4m E5AN-R3HMT-500 INSTRUCTION Manual.
Output status: ON into the light; light shading ON; switch conversion type.
Output: relay.
2 types of cost reductionProtective tubing diameter: D = 6.0.
Sleeve diameter Sleeve length: d = 8mm, l = 55mm.
tube thickness: 0.6 mm.
Lead wire length: 0.5m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5AN-R3HMT-500 INSTRUCTION Manual.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of thhe thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5AN-R3HMT-500 Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E5AN-R3HMT-500 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products
OMRON
Foundation type temperature controller
E5AN-R3PT-N
OMRON Foundation type temperature controller E5AN-R3PT-N
Size: 96 x 96mm. Ontology: terminal type