Lead wire length: 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5AN-Q3H01TD-FLK-N User's Manual
E5AN-Q3H01TD-FLK-N Fitting materials: Stainless steel (SUS304).
Count: 1 .
Accessories: Description, Hexagonal bolts M4 × 12,
(with spring and plain washers);
Material, Iron, zinc plating;
Count, 2.
Applicable sensor (mounting pitch on sensor side): E3S-C (horizontal type) E5AN-Q3H01TD-FLK-N User's Manual.
Page: Dimensions, 11. Name: Reflectors.
Directional angle: 30° min.
Ambient operating temperature range: -25 to 55°C.
Ambient storage temperature range: -40 to 70°C.
Ambient operating humidity range: 35% to 85%.
Ambient storage humidity range: 35% to 95%.
Degree of protection: IEC IP67.
Accessories: --. Appearance: M5.
Sensing distance: 3 mm.
Connecting method: M8 Pre-wired Connector Models (0 E5AN-Q3H01TD-FLK-N User's Manual. 3 m).
Cable specifications: PVC (oil-resistant).
Operation mode: NC.
Wire color /pin arrangement: 1: +V, 3: 0 V, 4: Control output.
Model: PNP output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5.4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available.
High-speed response frequency stably detects moving,
objects: 5 kHz max.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only).
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables. Size: 96 x 96mm.
Control output 1: relay.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: -.
Communication: -.
Break detection: -.
Power supply voltage: DC24V/AC24V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achievve 50ms E5AN-Q3H01TD-FLK-N MANUAL.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communicatiion E5AN-Q3H01TD-FLK-N MANUAL.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control.