LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
E5AN-HTPRR2BMD-500 User's Manual (Communications Functions)
Product model: E5AN-HTPRR2BMD-500
Name: Temperature Controller
Brand: OMRON
Sort: Communications Functions User's Manual
File language: English
E32-T25Y type: standard type; standard,
Specialty: plane shape (small) side,
Shape / detection distance (mm): 160; 130; 75 (30),
Bending radius (mm): R10.
Standard test object (minimum test object) (mm) 1: 1 (0.0005),
Fiber element for meeting diversified needsThe main body: terminal type, temperature input type E5AN-HTPRR2BMD-500 User's Manual.
Category: control output 2 point type (power supply AC100 ~ 240V) E5AN-HTPRR2BMD-500
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function E5AN-HTPRR2BMD-500 User's Manual.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5AN-HTPRR2BMD-500 User's Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes tthe process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5AN-HTPRR2BMD-500 MANUAL.
Through the infrared port can be carried out from the frront of the communication E5AN-HTPRR2BMD-500 MANUAL.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products