LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
E5AN-HSS2HH03BD-FLK INSTRUCTION Manual ()
Product model: E5AN-HSS2HH03BD-FLK
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Photomicrosensor with light,
modulation for reduced external,
light interference and a,
connector for easy maintenance.
Built-in connectors.
Select from four easy-to-use shapes for efficient space,
utilization.
Connectors with locks for safety against vibration.
Convenient mounting method using M3 screws E5AN-HSS2HH03BD-FLK INSTRUCTION Manual.
Wide operating voltage range: 5 to 24 VDC. Name: Small reflector E5AN-HSS2HH03BD-FLK
Directional angle: 30° min.
Ambient operating temperature range: -25 to 55°C.
Ambient storage temperature range: -40 to 70°C.
Ambient operating humidity range: 35% to 95%.
Ambient storage humidity range: 35% to 95%.
Degree of protection: IEC IP67.
Accessories: --. Control output 1: Voltage output.
Auxiliary output: Two E5AN-HSS2HH03BD-FLK INSTRUCTION Manual.
Communications: --.
Heater burnout: One.
Event inputs: Two.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to,
Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms E5AN-HSS2HH03BD-FLK INSTRUCTION Manual.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature.
Controllers to each other. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E5AN-HSS2HH03BD-FLK Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5AN-HSS2HH03BD-FLK Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Related products