E5AN-HAA3BFMD-500 INSTRUCTION Manual ()
Product model: E5AN-HAA3BFMD-500
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 20 cm.
Lead wire type: Heat resistive.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5AN-HAA3BFMD-500 INSTRUCTION Manual.
Ideal for the thermal input devices of Temperature Controllers E5AN-HAA3BFMD-500
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No E5AN-HAA3BFMD-500 INSTRUCTION Manual. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function E5AN-HAA3BFMD-500 INSTRUCTION Manual.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatiblle with Support Software (CX-Thermo version 4 E5AN-HAA3BFMD-500 Manual. 2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: M12 (Brass); Double; Shielded (See note 2.).
Sensing distance: 16 mm.
Connectting method (See note 1 E5AN-HAA3BFMD-500 Manual. ): M12 Connector.
Body length: Long.