E5AN-HAA2HHBFM-W-500 User's Manual (Communications Functions)
Product model: E5AN-HAA2HHBFM-W-500
Name: Temperature Controller
Brand: OMRON
Sort: Communications Functions User's Manual
File language: English
Amplifier Units.
Power supply/Output: DC/(NPN).
Timer function: Yes.
Self-diagnostic output: --.
Separate Amplifier Sensor with.
Sensitivity Adjustment.
Compact design with smaller Sensor Head.
Heat-resistance model available for application between.
-10 and 200°C. Size: 96 x 96mm.
Category: power AC100 ~ 240V with E5AN-HAA2HHBFM-W-500 User's Manual.
Shell color: silver.
Control output 1: output unit mode E5AN-HAA2HHBFM-W-500
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422 E5AN-HAA2HHBFM-W-500 User's Manual.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms E5AN-HAA2HHBFM-W-500 User's Manual.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Sensing method: Diffuse-reflective.
Connection method: Pre-wired M8 connector.
Sensing distance: 5 to 100 mm (wide view).
Model: PNP output .
The Standard for Photoelectric Sensors,

with a Secure Track Record of One,
Million Sold Yearly E5AN-HAA2HHBFM-W-500 MANUAL.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models.
Mechanical axis and optical axiss offset of less than ±2 E5AN-HAA2HHBFM-W-500 MANUAL. 5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light.