LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
E4B-RS70F4 INSTRUCTION sheet ()
Product model: E4B-RS70F4
Name: ultrasonic switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Size: M12 (Brass); Single; Shielded.
Sensing distance: 5 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Size: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 1 points E4B-RS70F4 INSTRUCTION sheet.
Power supply voltage: AC/DC24V.
Terminal type: PUSH-IN fastening terminal table type E4B-RS70F4
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 2 points.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc E4B-RS70F4 INSTRUCTION sheet. .
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal E4B-RS70F4 INSTRUCTION sheet.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately). Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic // manual, RUN/STOP, alarm), interactive display PV/SV E4B-RS70F4 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E4B-RS70F4 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Related products
OMRON
Ultrasonic Proximity Sensor
E4B-RS70E4
OMRON Ultrasonic Proximity Sensor E4B-RS70E4
Output configuration: DC switching NPN