Size: 48 x 48mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: - E3ZM-LS69H INSTRUCTION sheet.
Event input: -.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility
E3ZM-LS69H
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications E3ZM-LS69H INSTRUCTION sheet.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication E3ZM-LS69H INSTRUCTION sheet.
Combined temperature control device through component communication. E32-TC200B4R type: standard type; soft (new standard),
Specialty: M4 screw with casing,
Shape / detection distance (mm): 700; 530; 350 (140),
Standard test object
(minimum test object) (mm) 1: 1 (0.005),
Fiber element for meeting diversified needsName: End Unit *1.
Power supply voltage: 24 VDC.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 2 points (sinking).
Functions: burnout Heater alarm, None; Event inputs, None.
Communications functions: Port A or B: RS-485 Connector: Port A.
Input type: No input.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to thhe G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E3ZM-LS69H Manual.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullate the PID constants with the step,
response method E3ZM-LS69H Manual.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.