E3X-SRT21 INSTRUCTION sheet ()
Product model: E3X-SRT21
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 3 points (common universal).
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: - E3X-SRT21 INSTRUCTION sheet.
Communication: RS-485.
Event input: 1 points.
Remote SP input: - E3X-SRT21
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications E3X-SRT21 INSTRUCTION sheet.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication E3X-SRT21 INSTRUCTION sheet.
Combined temperature control device through component communication. Power supply voltage: 5 to 12 VDC.
Output configuration: Open-collector output (NPN output).
Output phases: Phases A and B.
Resolution (pulses/rotation): 100, 200, 360, 500.
Compact Encoder with External.
Diameter of 25 mm.
Incremental model.
External diameter of 25 mm.
Resolution of up to 500 ppr. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 4.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermoo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E3X-SRT21 Manual.
Through the infrared port can be carried out from the frront of the communication E3X-SRT21 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products
OMRON
Simple Fiber Amplifier Unit
E3X-NA11V 2M
OMRON Simple Fiber Amplifier Unit E3X-NA11V 2M
Item: Water-resistant models. Connectio
OMRON
Smart Fiber Amplifier Unit
E3X-CN12
OMRON Smart Fiber Amplifier Unit E3X-CN12
Type: Slave Connector. Cale length: 2
OMRON
Profibus-DP I/O link unit
CQM1-PRT21
OMRON Profibus-DP I/O link unit CQM1-PRT21
Numer of I/O points: 128 inputs and 12