E3JM-10M4 detection methods: the firing pattern,
Connection: terminal plate,
Detection range: 10m.
Output status: ON into the light; light shading ON; switch conversion type.
Output: relay.
2 types of cost reductionSize: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V) E3S-CT11-M1J INSTRUCTION sheet.
Shell color: black.
Control output: relay output
E3S-CT11-M1J
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / E3S-CT11-M1J INSTRUCTION sheet.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay E3S-CT11-M1J INSTRUCTION sheet.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. E32-T12F type: resistant to environmental type; resistant to drugs,
Specialty: Teflon coating for long distance,
Shape / detection distance (mm): 4000; 3000; 2000 (800),
Bending radius (mm): R40.
Standard test object (minimum test object) (mm) 1: 4 (0.1),
Fiber element for meeting diversified needsName: HFU with Programless Communications *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sinking).
Functions: burnout Heater alarm, None; Event inputs, 4.
Communications functions: Port C: RS-422,
From End Unit: Port A: RS-485.
Input type: No input.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the GG3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E3S-CT11-M1J Manual.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculaate the PID constants with the step,
response method E3S-CT11-M1J Manual.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.