E3S-AD93 INSTRUCTION sheet ()
Product model: E3S-AD93
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E3S-AD93 INSTRUCTION sheet.
Ideal for the thermal input devices of Temperature Controllers E3S-AD93
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output E3S-AD93 INSTRUCTION sheet.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 4.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E3S-AD93 INSTRUCTION sheet.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermmo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E3S-AD93 Manual.
Through the infrared port can be carried out from the frront of the communication E3S-AD93 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AD17
OMRON Built-in Amplifier Photoelectric Sensor E3S-AD17
Sensing method: Diffuse-reflective Senso
OMRON
Transparent Object Detection Sensor
E3S-RS30E42
OMRON Transparent Object Detection Sensor E3S-RS30E42
Sensing method: Retro reflective. Appea
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AD12
OMRON Built-in Amplifier Photoelectric Sensor E3S-AD12
Sensing method: Diffuse-reflective Senso
OMRON
PCB Sensors
E3S-LS3NT
OMRON PCB Sensors E3S-LS3NT
Sensing method: Convergent reflective.