Protective tubing length (mm): M8 screw.
Lead wire length: 4 m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers E2FQ-X10D1 INSTRUCTION sheet.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal
E2FQ-X10D1 E3T-SR12 detection methods: Regression reflection type,
Connection mode: lead wire,
Output status: shading ON,
Output mode: NPN output,
Long distance photoelectric sensor to realize the regression reflection
Type 10m distance setting 2mProgrammable Controllers Join the Series!
Program up to 256 segments and take,
advantage of the high cost performance,
of the new LCD that improves both the,
field of view and contrast E2FQ-X10D1 INSTRUCTION sheet.
Set up to 8 programmed patterns with up to 32 segments (steps) each.
High-resolution display with 5 digits/0.01°C display in a compact,
Controller (48 x 48 mm).
High-speed sampling cycle of 60 ms E2FQ-X10D1 INSTRUCTION sheet.
High Accuracy.
Thermocouple/Pt input: ±0.1% of PV,
Analog input: ±0.1% FS,
Universal inputs on all models (thermocouple, PT, or analog,
input) to handle various sensors with one Controller.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/RESET, and alarms) and the PV or SV.
Flexible contact outputs with logic operations (AND, OR, and,
delays) set from the Support Software (CX-Thermo version 4.3).
Program settings can be managed.
Preventive maintenance for relays in the Temperature Controller,
using a Control Output ON/OFF Counter. Sensing method: Retro-reflective Sensors.
Appearance: Horizontal.
Connection method: Pre-wired.
Sensing distance: 7 m.
Functions: --.
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Size: 48 x 48mm.
Body: terminal type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event input points: -.
Transfer output: -.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E2FQ-X10D1 Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault