LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
E2E-S05N03-CJ-B1 INSTRUCTION sheet ()
Product model: E2E-S05N03-CJ-B1
Name: proximity sensor
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Size: M8(Stainless steel)(See note 2.); Single; Shielded.
Sensing distance: 1.5 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Short.
Output configuration: NPN.
Operation mode NO.
A new generation in global applications. Size: M8(Stainless steel)(See note 2.); Double; Unshielded E2E-S05N03-CJ-B1 INSTRUCTION sheet.
Sensing distance: 4 mm.
Connecting method (See note 1 E2E-S05N03-CJ-B1): M8 Connector (3-pin).
Body length: Short.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Continuation of the E6B2 high cost, value also have more choice.
E6B3, E6C4 blockbuster debut! Complementary output of the first starting high anti interference.
40mm diameter, shaft diameter of phi 8mm universal, with strong axial load capacity E2E-S05N03-CJ-B1 INSTRUCTION sheet.
50mm diameter, shaft diameter of phi 10mm rugged, with strong axial load capacity,
At the same time, the use of IP65 anti drip, anti oil structure.
E6B2 complementary output will be issued over the same period.
Connection length to reach a full 30m!
Resolution (pulse / rotation):10~3600P/R.
Power supply voltage: DC12 ~ 24V
Consumption current: 100mA below E2E-S05N03-CJ-B1 INSTRUCTION sheet.
Output state: complementary output.
Maximum response frequency: 100kHz.
Output phase difference: A phase, B phase difference 90 plus or minus 45.
Starting torque: M / 10mN below (at room temperature).
Maximum allowable speed: 5000r/min.
Axial force: radial...... 120N, axial...... 50N. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E2E-S05N03-CJ-B1 Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E2E-S05N03-CJ-B1 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products