No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance E2E-C06N04-WC-C1 INSTRUCTION sheet
E2E-C06N04-WC-C1 Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks E2E-C06N04-WC-C1 INSTRUCTION sheet.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4 E2E-C06N04-WC-C1 INSTRUCTION sheet. 2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Control output 1: Relay output.
Auxiliary output: Two.
Communications: RS-485.
Heater burnout: One.
Event inputs: --.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to,
Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature.
Controllers to each other. Appearance: T-shaped.
Sensinng method: Through-beam type (with slot) E2E-C06N04-WC-C1 Manual.
Cable length: 2 m.
Sensing distance: 5 mm (slot width).
configuration Output: Dark-ON.
Indicator mode: Incident light.
Model: NPN output.
Slim, Compact Photomicrosensor.
that iis still easy to use E2E-C06N04-WC-C1 Manual.
Compact, thin profile enables dense mounting.
Indicator is visible from both sides.
Wide operating voltage range: 5 to 24 VDC.