D4N-8D31 INSTRUCTION sheet ()
Product model: D4N-8D31
Name: safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF cable *2.
Actuator: Pin plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection D4N-8D31 INSTRUCTION sheet.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4N-8D31
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers D4N-8D31 INSTRUCTION sheet.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Actuator: Fork lever lock (left operation).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches D4N-8D31 INSTRUCTION sheet.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Plunger.
Conduit openings: G1/2 (PF1/2).
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the leever D4N-8D31 Manual.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4N-8D31 Manual.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Related products
OMRON
Safety Limit Switch
D4N-8B72
OMRON Safety Limit Switch D4N-8B72
Actuator: One-way roller arm lever vert
OMRON
Pull-reset Safety Limit Switch
D4N-1A31R
OMRON Pull-reset Safety Limit Switch D4N-1A31R
Actuator: Plunger. Conduit size: 1-cond
OMRON
Safety Limit Switch
D4N-222H
OMRON Safety Limit Switch D4N-222H
Actuator: Adjustale roller lever, form
OMRON
Safety Limit Switch
D4N-4E32
OMRON Safety Limit Switch D4N-4E32
Actuator: Roller plunger. Conduit size: