LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
D4N-8C62R INSTRUCTION sheet ()
Product model: D4N-8C62R
Name: pull-reset safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Release Key Type: Special (resin).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @ D4N-8C62R INSTRUCTION sheet.
Conduit size (See Note.): 1/2-14NPT D4N-8C62R
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available) D4N-8C62R INSTRUCTION sheet.
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors D4N-8C62R INSTRUCTION sheet. Short/disconnection detection: Not supported.
Specifications: Inputs, NPN (+ common), 16 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals. Release key type: Special release key.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+2NC/1NO.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits aand two monitor contacts provide an,
array of monitoring patterns D4N-8C62R Manual.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas. D4N-8C62R Manual.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection.
Related products
OMRON
Safety Limit Switch
D4N-8D62
OMRON Safety Limit Switch D4N-8D62
Actuator: One-way roller arm lever hori
OMRON
Safety Limit Switch
D4N-6272
OMRON Safety Limit Switch D4N-6272
Actuator: One-way roller arm lever vert
OMRON
Safety Limit Switch
D4N-4B87
OMRON Safety Limit Switch D4N-4B87
Actuator: Plastic rod. Conduit size: 1-
OMRON
Safety Limit Switch
D4N-8B2G
OMRON Safety Limit Switch D4N-8B2G
Actuator: Adjustale roller lever, form