D4N-5C62 INSTRUCTION sheet ()
Product model: D4N-5C62
Name: safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Release key type: Special release key.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+3NC.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns D4N-5C62 INSTRUCTION sheet.
Standard gold-clad contacts enable use with ordinary loads,
and microloads D4N-5C62
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. A reliable basic switch with an external lever
Can use 0 D4N-5C62 INSTRUCTION sheet. 1A, 6A, 11A, 16A and 21A models,
All models have a self - cleaning connection.
Custom leverage can be used externally or internally,
And 2 fixed positions of the external lever.
Consistent with EN61058-1 and UL1054.
Model composition:
D3V- - - - - - - - - - - - -
The 4 5 6 7 8 9
Rated value
AC250V 21: 20 (4) A
AC250V 16: 16 (3) A
AC250V 11: 11 (3) A
AC250V 6: 6 (2) A
AC125V 0 D4N-5C62 INSTRUCTION sheet. 1A 01:
Contact interval
No mark: 1mm (Gap F)
G:0.5mm (Gap G)
Driving rod
No mark: needle button type
1: short swing rod type
2: swing lever type
3: long swing rod type
R 4: type swing lever type
5: ball short swing rod type
6: ball type
The installation position of the sensors
No mark: internal installation, the button switch is far from the reference position
M: external installation, the button switch is far from the reference position
K: external installation, the button switch is close to the reference position.
Contact the specifications
SP DT 1:
SP ST-NC 2:
SP ST-NO 3:
The terminal specificatiion
A: welding terminal
#187 C2: type terminal
#250 C: type terminal
The maximum operating force (OF)
5: 1 D4N-5C62 Manual. 96 N
4A: 1.23 N
4: 0.98 N
3: 0.49 N
2: 0.25 N
Note that the numerical value is a needle like button type.
We take tthe size of mounting hole
No mark: 3 D4N-5C62 Manual. 1mm
2.9mm K:
9 special code
No mark: Standard
H: high temperature (125 degrees C)
E: special rating: 21 (8) A
Related products
OMRON
Safety Limit Switch
D4N-2E32
OMRON Safety Limit Switch D4N-2E32
Actuator: Roller plunger. Conduit size:
OMRON
Safety Limit Switch
D4N-2A22
OMRON Safety Limit Switch D4N-2A22
Actuator: Roller lever resin lever, res
OMRON
Safety Limit Switch
D4N-4ELE
OMRON Safety Limit Switch D4N-4ELE
Actuator: Fork lever lock left operatio
OMRON
Safety Limit Switch
D4N-9A25
OMRON Safety Limit Switch D4N-9A25
Actuator: Roller lever resin lever, met