LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
D4N-4A72 INSTRUCTION sheet ()
Product model: D4N-4A72
Name: safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Drive rod: needle like button type.
Specifications: plastic wire terminal.
The protection structure is in conformity with the JIS''s anti immersion type, IP67 IEC (except for the terminal part).
Can be used in the environment temperature -40 ~ +85.
Through the use of gold alloy bar, contact springs to achieve longevity and high contact reliability D4N-4A72 INSTRUCTION sheet. Type: one touch type connector, small load D4N-4A72
Rated current; 5A AC125V.
Driving rod: ball type.
Terminal: DC connector.
Action indicator: no operation indicator.
Compared with D4E performance is stronger, in compliance with the requirements of high durability, high sealing.
Horizontal spring, with improved swing lever ratio of the built-in switch to provide a smooth action effect and a longer period of use D4N-4A72 INSTRUCTION sheet.
Protection cover protects built-in switch from dust and oil pollution damage.
The plunger type combined with the solid sealing cover has longer service life.
One touch off connector wiring operation miscellaneous,
And reduce the downtime due to wiring and maintenance.
Gold Plated minimum load type is an ideal choice for electronic control D4N-4A72 INSTRUCTION sheet.
Can provide terminal type plastic screw terminal system and terminal type plastic with operation indicator.
Certified by EN, UL, CSA and CCC (China Standard) standard.
Install the pitch and with the characteristics of D4E- - N and D4E. Type: 1-conduit.
Mounting direction: Front-side mounting.
Conduit size: M20.
1NC/1NO (Slow-action).
The Special Operation Key Activates a Direct.
Opening Mechanism to Open the Contacts.
and Shut Off Control Circuits when Protective.
Doors Are Opened on Machine Tools or Other.
Equipment.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL and CSA standdards D4N-4A72 Manual.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened. The EN-certified.
direct opening mechanism is indicated by on the Switch.
Malfunctions and false operationn prevented by special Operation Key D4N-4A72 Manual.
Wide temperature range specifications: −40 to 80°C.
Degree of protection of the switch box: IP67 (EN60947-5-1).
Related products
OMRON
Pull-reset Safety Limit Switch
D4N-2D20R
OMRON Pull-reset Safety Limit Switch D4N-2D20R
Actuator: Roller lever resin lever, res
OMRON
Pull-reset Safety Limit Switch
D4N-2B20R
OMRON Pull-reset Safety Limit Switch D4N-2B20R
Actuator: Roller lever resin lever, res
OMRON
Safety Limit Switch
D4N-2C31
OMRON Safety Limit Switch D4N-2C31
Actuator: Plunger. Conduit size: 1-cond
OMRON
Safety Limit Switch
D4N-2C25
OMRON Safety Limit Switch D4N-2C25
Actuator: Roller lever metal lever, met