LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
D4N-2D2GR INSTRUCTION sheet ()
Product model: D4N-2D2GR
Name: pull-reset safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Type of drive rod: roller plunger type.
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (1NC/1NO).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC) D4N-2D2GR INSTRUCTION sheet.
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm D4N-2D2GR
Elevator and escalator can be used. Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @ D4N-2D2GR INSTRUCTION sheet.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices D4N-2D2GR INSTRUCTION sheet.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors. Short/disconnection detection: Supported.
Specifications: Outputs, NPN (- common), 32 points.
I/O connectionns: Clamp terminals D4N-2D2GR Manual.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw--less structure eliminates tightening work D4N-2D2GR Manual.
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals.
Related products
OMRON
Safety Limit Switch
D4N-2222
OMRON Safety Limit Switch D4N-2222
Actuator: Roller lever resin lever, res
OMRON
Pull-reset Safety Limit Switch
D4N-2D20R
OMRON Pull-reset Safety Limit Switch D4N-2D20R
Actuator: Roller lever resin lever, res
OMRON
Safety Limit Switch
D4N-4280
OMRON Safety Limit Switch D4N-4280
Actuator: Cat whisker. Conduit size: 1-
OMRON
Safety Limit Switch
D4N-4231
OMRON Safety Limit Switch D4N-4231
Actuator: Plunger. Conduit size: 1-cond