LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
D4N-2ARE INSTRUCTION sheet ()
Product model: D4N-2ARE
Name: pull-reset safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed pin plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4N-2ARE INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection D4N-2ARE
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers D4N-2ARE INSTRUCTION sheet.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Solenoid lock Mechanical release D4N-2ARE INSTRUCTION sheet.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key innsertion point D4N-2ARE Manual.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4N-2ARE Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Safety Limit Switch
D4N-1F25
OMRON Safety Limit Switch D4N-1F25
Actuator: Roller lever metal lever, met
OMRON
Safety Limit Switch
D4N-4A20
OMRON Safety Limit Switch D4N-4A20
Actuator: Roller lever resin lever, res
OMRON
Pull-reset Safety Limit Switch
D4N-6A32R
OMRON Pull-reset Safety Limit Switch D4N-6A32R
Actuator: Roller plunger. Conduit size:
OMRON
Pull-reset Safety Limit Switch
D4N-4A20R
OMRON Pull-reset Safety Limit Switch D4N-4A20R
Actuator: Roller lever resin lever, res