LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
D4JL-2PFG-D5 INSTRUCTION sheet ()
Product model: D4JL-2PFG-D5
Name: guard lock safety-door switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Plastic rod.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection D4JL-2PFG-D5 INSTRUCTION sheet.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4JL-2PFG-D5
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers D4JL-2PFG-D5 INSTRUCTION sheet.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Actuator: One-way roller arm lever (horizontal).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 3NC (Slow-action).
A Series of Pull-reset Models Now D4JL-2PFG-D5 INSTRUCTION sheet.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Direction of Operation Key insertion: Horizontal.
Cable length: 1 m.
2NC/1NO (Slow-action).
Slim Safety Door Switches with IP67 Rating.
Slim design with a width of only 17 mm.
(three-contact models).
Reversible design allowing either front or rear mounting.
Built-in Switches with two- or three-terminal contact.
construction are available.
Operation Key with rubber mounting hole to absorb vibration and shock.
IP67 degree of protection. The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standardd operating temperature range:
-40°C to +100°C (standard type) D4JL-2PFG-D5 Manual.
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models aavailable for complex operations D4JL-2PFG-D5 Manual.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)
Related products