D4F-420-1D INSTRUCTION sheet ()
Product model: D4F-420-1D
Name: safety door switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Classification: Analog input.
I/O points: 4 inputs (Resolution: 6, 000).
Performs Calculations on Analog Values within the Slave Itself.
Also Provides High Resolution at 1/30,000 (Full Scale) and,
Support for a Wide Variety of Data Sampling.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities D4F-420-1D INSTRUCTION sheet D4F-420-1D
Sampling data can be analyzed internally to provide a low-cost scheduler function.
Equipped with functions such as the scaling function, peak/bottom hold;
top/valley hold; comparator function, cumulative counter, and derivative,
calculation function.
Two I/O points can be allocated to any two of the following values: analog,
input, peak/bottom, top, valley, or rate-of-change D4F-420-1D INSTRUCTION sheet. Values without an,
allocated I/O point can be read with message communications. Actuator type: Roller lever.
Compact Vertical Models Sized for Asian.
Standards.
Compact new design approximately 1/3 the size of OMRON,
vertical Limit Switches.
Structure enables the terminal section to be fully opened for,
easy wiring.
RoHS complaint D4F-420-1D INSTRUCTION sheet.
Degree of protection: IP65. Actuator: One-way roller arm lever (vertical).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key inseertion point D4F-420-1D Manual.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4F-420-1D Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Small Safety Limit Switch
D4F-402-1D
OMRON Small Safety Limit Switch D4F-402-1D
Actuator: Roller plunger Metal roller.
OMRON
Small Safety Limit Switch
D4F-420-3D
OMRON Small Safety Limit Switch D4F-420-3D
Actuator: Roller lever Metal lever, res
OMRON
Small Safety Limit Switch
D4F-120-1D
OMRON Small Safety Limit Switch D4F-120-1D
Actuator: Roller lever Metal lever, res
OMRON
Small Safety Limit Switch
D4F-420-1R
OMRON Small Safety Limit Switch D4F-420-1R
Actuator: Roller lever Metal lever, res