Output method: Relay.
Inputs: ---.
Outputs: 16.Product name: N@@S1- type CPU Units with 40 I/O Points.
Specifications: Power Supply, DC24V; Inputs, 24; Outputs, 16;
Output type: Transistor (sinking).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0 CRT1-ROS08 UL Standards and CSA Standards. 31A; 24 V,0.02A.
Standards: CE
CRT1-ROS08
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Model: C200HW-CORT21-V1 CRT1-ROS08 UL Standards and CSA Standards.
C200HW C Communications CANopen Master / Slave Unit C200HWCORT21C500-OA I/O Unit Triac Output 16 pts C500-OA226.
AC250V 1.2A.Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 32 outputs(High speed);
Maximum switching capacity, 24VDC, 0.5A;
Commons, 16 points, 1 common;
External connection, MIL connector CRT1-ROS08 UL Standards and CSA Standards.
No. of words allocated: 2 words.
Current consumption: 5V, 0.22A; 24V, --.
Standards: N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput.
Name: Loop-control CPU Unit.
I/O bits: 960 bits.
Program capacity: 20K steps.
DM words: 32K words.
EM words: 32K words × 1 bank E0_00000 to E0_32767.
Versatile Machine Control with the,
Highest Performance Standards in the Industry. NO. OF I/O SLOTS: 5 SLOTSName: e-CON Connector Type.
Specifications: Analog outputs;
2 outputs.
Standards: CE, UC, UC1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CRT1-ROS08 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CRT1-ROS08 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.