Model: C500-ETL01.
C500-ET Special I/O Unit Educational Tool I/O Unit C500-ETL01.Name: Temperature Control Module.
Model: C200H-TC002.
Sensor: Thermocouple: R, S, K(CA), J(IC), T(CC), E(CRC), B, N, L(IC), U(CC).
Control output: Voltage output.Unit classification: CJ1 CPU Bus Unit.
Specifications:Equipped with Master,
and Slave functionality CRT1-OD16TA UL Standards and CSA Standards.
Controls for up to 32,000 points per Master
CRT1-OD16TA
Communications:Remote I/O Communications,
Master (fixed allocations or user-set,
allocations) Remote I/O Communications,
Slave (fixed allocations or user-set,
allocations) Message communica29A; 24V,--.
Smallest in the Industry!
A DeviceNet Unit for the,
CJ Series that Boasts Industry-leading,
Performance and Functions CRT1-OD16TA UL Standards and CSA Standards.
Model: C200H-IA221.
No. of inputs: 8 pts.
Input voltage: 200 to 240 VAC, +10%/–15%.
Input current: 10mA, 200VAC.
Isolation: Photo-coupler.
Indica-tor: LED.
External connec-tions: Remove-able termi-nal blocks.
Inputs percom-mon: 8 pts.
Internal currentcon-sump-tion: Connecting I/O control module and interface module.
Cable length: 0.7 m.Unit type: CJ1 Basic I/O Units.
Product name: DC Input/Transistor Output Units CRT1-OD16TA UL Standards and CSA Standards.
Specifications: Output type, Sourcing;
I/O points, 16 inputs, 16 outputs;
Input voltage,Input current, 24VDC, 7mA,
24VDC, 0.5A Short-circuit protection;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 4 words.
Current consumption: 5V, 0.13A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Mixed,
I/O Units for Different Applications,
and Wiring Methods.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems. C1000H-CP CPU 62 k words 1024 pts C1000H-CPU01-E.Model : C500-BP001.
Optional extension cable is necessary..C500-CT Special I/O Unit High-speed Counter Unit 20 kcps 4 pts C500-CT041.Name: Temperature Input Units.
Specifications: Thermocouple Input; 4 inputs;
Switchable between.
(R, S, K, J, T, E, B, N, L, U, W, PL2)
Standards: CE, UC, UC1, N .
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost ccan be reduced CRT1-OD16TA Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CRT1-OD16TA Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.