Used for data input and process value display for the C200H-TC---, C200H-TV---, C200H-CP114, and C200H-PID0-.Name: Connector.
Model: C200H-CE002.Applicable CPU Units: CQM1H-CPU51/61.
Pulse inputs: 4 inputs.
External outputs: 4 outputS.
Current consumption (Supplied from Power Supply Unit): 5 V DC, 400 mA max CPM1A-10CDR-A-V1 I/O Wiring Diagram.
Dimensions: 25 × 110 × 107 mm (W × H × D).
Weight: 90 g max
CPM1A-10CDR-A-V1
2 platinum resistance thermometer inputsName: Screw Terminal Block with Relay Outputs.
Specifications: Outputs;
16 outputs; Contacts.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CPM1A-10CDR-A-V1 I/O Wiring Diagram.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Model: CPM2C-16ETM. Units with transistor outputs only.
1 MIL connector CPM1A-10CDR-A-V1 I/O Wiring Diagram.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sinking transistor.Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs: Open collector,
PNP outputs (pulses).
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output. Name: Two-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can bee reduced CPM1A-10CDR-A-V1 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CPM1A-10CDR-A-V1 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.