I/O capacity: 512 pts (2, 048 max. with remote I/O).
Execution time: Basic: 0.15 µs min.Special: 0.6 µs min.
Model: CPM2A-60CDR-A. Power supply: AC power supply.
Output type: Relay.
Inputs points: 36 points.
Outputs points: 24 points.Unit type: CS1 Basic I/O Units.
Product name: Relay Output Units CJ1M-CPU12-ETN INSTRUCTIONS REFERENCE MANUAL.
Specifications: 12 to 24 VDC,
0.1 A 96 outputs; Sinking
CJ1M-CPU12-ETN
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 6 words.
Current consumption: 5V system, 0.48A;
26 V system, --.
Standards: U, C, N, L, CE CJ1M-CPU12-ETN INSTRUCTIONS REFERENCE MANUAL.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. I/O capacity: 2.048 pts (6, 144 max. with remote I/O).
Execution time: Basic: 0.125 µs min.Special: 0.5 µs min.
Name: Heat/Cool Temperature Control Module.
Model: C200H-TV102.
Sensor: Platinum resistance thermometer: JPt100, Pt100.
Control output: Voltage output(transistor output used for cooling outputs) CJ1M-CPU12-ETN INSTRUCTIONS REFERENCE MANUAL. Unit type: CS1 Basic I/O Units.
Product name: DC Input/Transistor Output Unit.
Specifications: 24 VDC, 6 mA 32 inputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 2 input words and 2 output words.
Current consumption: 5V system, 0.27A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Unit type: CS1 Special I/O Units.
Product name: Analog Input Unit (100 mV).
Input points : 8 inputs.
Signal range: 0 to 100 mV, ±100 mV.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CJ1M-CPU12-ETN Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1M-CPU12-ETN Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.